Technical Diagnostics & Fault Codes β’ Heat Pumps (Panasonic Aquarea & Mitsubishi Zubadan)
Panasonic H62, H70, F20 & Mitsubishi L9, P8, U1 Fault Codes β Error Code Meaning, Troubleshooting & Repair
Complete diagnostic table of the most common faults for Panasonic & Mitsubishi (Heat Pumps (Panasonic Aquarea & Mitsubishi Zubadan)) with quick troubleshooting steps and links to replacement parts:
Error Code Reference Table for Panasonic & Mitsubishi and step-by-step repair procedure:
| Error Code | Meaning / Fault Symptom | Most Common Cause & Repair Procedure |
|---|---|---|
| H62 (Panasonic) / L9 (Mitsubishi) | Low water flow rate in heating circuit | Clean the water strainer mesh and magnetic dirt separator, bleed the circulation pump, and verify underfloor heating loops are open. |
| H70 / F20 | Backup bivalent immersion heater overload / high compressor discharge temperature | Reset the manual thermal cut-out button on the backup heater element or check its dedicated circuit breaker. |
| F36 / H72 | Faulty outdoor ambient temperature sensor or DHW cylinder sensor | Replace the NTC temperature probe (thermistor) inside the DHW tank pocket. |