Technical Diagnostics & Fault Codes β’ Boilers & Heat Pumps (ecoTEC / aroTHERM)
Vaillant Fault Codes F.28, F.22, F.75, F.29, F.62 β Error Code Meaning, Troubleshooting & Repair
Complete diagnostic table of the most common faults for Vaillant (Boilers & Heat Pumps (ecoTEC / aroTHERM)) with quick troubleshooting steps and links to replacement parts:
Error Code Reference Table for Vaillant and step-by-step repair procedure:
| Error Code | Meaning / Fault Symptom | Most Common Cause & Repair Procedure |
|---|---|---|
| F.28 / F.29 | Ignition failure / flame loss during operation | Closed gas supply valve, faulty ignition/ionization electrode, defective gas valve assembly, or frozen condensate drain pipe. |
| F.22 | Heating system water pressure too low (below 0.5 bar) | Top up system water pressure to 1.2 β 1.5 bar via the filling loop; if pressure drops repeatedly, check the expansion vessel or safety relief valve. |
| F.75 | No pressure jump detected when the circulation pump starts | Clogged/faulty Vaillant water pressure sensor (most common cause!), airlocked system, or seized circulation pump. |