Technical Diagnostics & Fault Codes β€’ Gas & Electric Boilers (Panther / Ray / Gepard)

Protherm Fault Codes F.22, F.28, F.75, F.10, F.20 – Error Code Meaning, Troubleshooting & Repair

Complete diagnostic table of the most common faults for Protherm (Gas & Electric Boilers (Panther / Ray / Gepard)) with quick troubleshooting steps and links to replacement parts:

Error Code Reference Table for Protherm and step-by-step repair procedure:

Error Code Meaning / Fault Symptom Most Common Cause & Repair Procedure
F.22 Insufficient water in heating system (pressure below 0.6 bar) Open the filling valve underneath the boiler and pressurize to 1.2 – 1.5 bar; replace the clogged water pressure sensor if needed.
F.28 / F.29 Ignition failure / flame loss Dirty ionization electrode, blocked condensate trap/siphon, or gas valve fault.
F.20 Boiler overheating (high-limit safety thermostat tripped) Faulty Wilo/Grundfos circulation pump or seized 3-way diverter valve.