Technical Diagnostics & Fault Codes • Gas & Condensing Boilers (Baxi Duo-tec, Luna, Nuvola & De Dietrich)
Baxi & De Dietrich Error Codes: E01, E10, E25/E26, E110, E133 – Error Code Meaning, Troubleshooting & Repair
Complete diagnostic table of the most common faults for Baxi & De Dietrich (Gas & Condensing Boilers (Baxi Duo-tec, Luna, Nuvola & De Dietrich)) with quick troubleshooting steps and links to replacement parts:
Error Code Reference Table for Baxi & De Dietrich and step-by-step repair procedure:
| Error Code | Meaning / Fault Symptom | Most Common Cause & Repair Procedure |
|---|---|---|
| E01 | Burner ignition failure / flame loss (ignition lockout) | Closed gas valve, dirty ignition or ionization electrode, reversed live/neutral polarity in the wall socket, or faulty gas valve; after checking, hold the Reset (R) button for 2 seconds. |
| E10 / E118 | Heating water pressure too low in the system (below 0.5 bar) | Open the filling tap underneath the Baxi boiler and top up water pressure to 1.2 – 1.5 bar; if pressure drops frequently, repressurize the expansion vessel or replace the hydraulic pressure switch. |
| E25 / E26 | Maximum temperature rise rate exceeded / blocked circulation pump | Insufficient heating water circulation through the exchanger – bleed the boiler, clean the return strainer mesh, and free the circulation pump rotor shaft if seized. |
| E110 | Safety high-limit overheating thermostat (STB) or flue gas thermostat tripped | The boiler overheated above 100 °C due to closed radiator valves, an airlocked heat exchanger, or a faulty heating water NTC temperature sensor; let the boiler cool down and press Reset. |
| E133 / E128 | Gas supply interruption / flame loss on Baxi Duo-tec & De Dietrich condensing boilers | Clogged condensate drain trap (water flooded the combustion chamber!), frozen flue terminal in winter, worn ionization electrode, or gas valve calibration required. |