🔧 Vaillant 🔧 Viessmann 🔧 Protherm 🔧 Daikin 🔧 Panasonic & Mitsubishi 🔧 Fronius / GoodWe / Solax 🔧 Bosch / Siemens 🔧 AEG / Electrolux 🔧 LG & Samsung 🔧 DeLonghi / Philips / Krups 🔧 Baxi & De Dietrich 🔧 Junkers / Buderus / Bosch 🔧 Panasonic Aquarea & NIBE 🔧 Solax / Huawei / Growatt 🔧 Whirlpool & Indesit 🔧 Beko 🔧 Gorenje & Mora 🔧 Krups / Jura / Nivona 🔧 Bosch eBike / Bafang / Shimano 🔧 Xiaomi & Ninebot 🔧 Husqvarna / Gardena / Parkside 🔧 Webasto & Eberspächer
Technical Diagnostics & Fault Codes • Gas & Condensing Boilers (Baxi Duo-tec, Luna, Nuvola & De Dietrich)

Baxi & De Dietrich Error Codes: E01, E10, E25/E26, E110, E133 – Error Code Meaning, Troubleshooting & Repair

Complete diagnostic table of the most common faults for Baxi & De Dietrich (Gas & Condensing Boilers (Baxi Duo-tec, Luna, Nuvola & De Dietrich)) with quick troubleshooting steps and links to replacement parts:

Error Code Reference Table for Baxi & De Dietrich and step-by-step repair procedure:

Error Code Meaning / Fault Symptom Most Common Cause & Repair Procedure
E01 Burner ignition failure / flame loss (ignition lockout) Closed gas valve, dirty ignition or ionization electrode, reversed live/neutral polarity in the wall socket, or faulty gas valve; after checking, hold the Reset (R) button for 2 seconds.
E10 / E118 Heating water pressure too low in the system (below 0.5 bar) Open the filling tap underneath the Baxi boiler and top up water pressure to 1.2 – 1.5 bar; if pressure drops frequently, repressurize the expansion vessel or replace the hydraulic pressure switch.
E25 / E26 Maximum temperature rise rate exceeded / blocked circulation pump Insufficient heating water circulation through the exchanger – bleed the boiler, clean the return strainer mesh, and free the circulation pump rotor shaft if seized.
E110 Safety high-limit overheating thermostat (STB) or flue gas thermostat tripped The boiler overheated above 100 °C due to closed radiator valves, an airlocked heat exchanger, or a faulty heating water NTC temperature sensor; let the boiler cool down and press Reset.
E133 / E128 Gas supply interruption / flame loss on Baxi Duo-tec & De Dietrich condensing boilers Clogged condensate drain trap (water flooded the combustion chamber!), frozen flue terminal in winter, worn ionization electrode, or gas valve calibration required.