Technical Diagnostics & Fault Codes β’ Gas Condensing Boilers (Junkers Cerapur, Buderus Logamax & Bosch Condens)
Junkers, Buderus & Bosch Error Codes: EA / 6A, CE / H07, A7, C6, E9 β Error Code Meaning, Troubleshooting & Repair
Complete diagnostic table of the most common faults for Junkers / Buderus / Bosch (Gas Condensing Boilers (Junkers Cerapur, Buderus Logamax & Bosch Condens)) with quick troubleshooting steps and links to replacement parts:
Error Code Reference Table for Junkers / Buderus / Bosch and step-by-step repair procedure:
| Error Code | Meaning / Fault Symptom | Most Common Cause & Repair Procedure |
|---|---|---|
| EA / 6A (227) | No flame detected after ignition attempt (missing ionization current) | Check that the main gas shut-off valve is open, clean the condensate trap, and inspect the ignition/ionization electrode; fluctuating gas supply pressure or a faulty control board are also common causes. |
| CE / H07 (1017) | Low water pressure in the heating system (below the 0.6 bar minimum threshold) | Refill the heating circuit via the filling loop to 1.2 β 1.5 bar; if the pressure rapidly climbs toward 3 bar when heated, the expansion vessel diaphragm has lost its air charge. |
| A7 / AD | Faulty domestic hot water temperature sensor (DHW / cylinder NTC probe) | Broken wire or defective NTC thermistor for hot water heating in the storage tank or plate heat exchanger; measure the sensor resistance with a multimeter and replace the NTC probe. |
| C6 / 3C (215) | Flue gas fan not running or air pressure switch (manostat) failed to close | Differential pressure switch silicone tubes blocked by condensate, obstructed coaxial flue pipe, or worn flue fan bearings. |
| E9 / D4 (224) | Heat exchanger safety temperature limiter (STB) tripped | Insufficient water flow through the primary heat exchanger β verify circulation pump operation, open radiator thermostatic valves, and bleed the pump. |